Description · from the CVE record

This issue occurs when NGINX Plus or NGINX Open Source is configured as a proxy, the proxied server name includes variables, and a Server Side Includes (SSI) or mirror directive sends a subrequest to a location that resolves the same server name. Under these conditions, a specially crafted HTTP request may cause a use-after-free condition in a worker process. An attacker may also be able to execute code if Address Space Layout Randomization (ASLR) is disabled or the attacker can bypass ASLR. Impact: An attacker could leverage this vulnerability to crash the NGINX worker process, corrupt its memory, or perform remote code execution (RCE) Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Affected

ProductAffectedFixed inSource
NGINX Plus37.1.0 – < 37.3.0.137.3.0.1CNA
NGINX Plus37.0.0 – < 37.0.8.137.0.8.1CNA
NGINX PlusR33–CNA
NGINX Open Source1.31.0 – < 1.31.91.31.9CNA
NGINX Open Source1.30.0 – < 1.30.71.30.7CNA
NGINX Open Source0.6.18–CNA
Industrial Edge Cloud Device (IECD)all versions–siemens-SADP
Industrial Edge Device Kit - arm64all versions–siemens-SADP
Industrial Edge Device Kit - x86-64all versions–siemens-SADP
Industrial Edge Hubsee advisory–siemens-SADP
Industrial Edge Management Cloudsee advisory–siemens-SADP
Industrial Edge Management Pro V1see advisory–siemens-SADP

Scores by source

f5 (CNA)9.2CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
f5 (CNA)8.1CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA ADPSSVCExploitation: none · Automatable: no · Technical impact: total

References

patchmy.f5.com/manage/s/article/K000163925refcert-portal.siemens.com/productcert/html/ssa-935812.html